Grupy produktów > Environmental Sensors > HW group WLD-Location cable

HW group WLD-Location cable

Detects a water leak and pinpoints its location along the cable

HW group WLD-Location cable
8626_38959.png
8626_38960.png
8626_38961.png
8626_38962.png
8626_38963.png
8626_38964.png
8626_38965.png
8626_38966.png
  • CechyCechy
  • PrezentacjaPrezentacja
  • Więcej informacjiWięcej informacji
  • PDFPDF
  • Water is detected along the entire length of the cable
  • Water leak location

The WLD-Location cable L detects flooding and determines the distance to the point where liquid is detected. When flooding occurs inside buildings or data centers, every second counts. Locating the flooding point makes it possible to quickly identify the exact location, even beneath floors or in inaccessible areas. The WLD-Location cable indicates the location of water, glycol, or other conductive liquid leaks.

The WLD-Location cable L is a sensing cable for detecting water and conductive liquids that also identifies where along the cable the leak occurred. Unlike standard WLD Type A and Type B sensing cables, which only report the presence of liquid somewhere within the entire zone, Type L also locates the position of the leak. Use it where detecting a leak is not enough and its exact location must also be identified. The maximum length of one WLD-L zone is 100 m.


Typical applications
  • Data centers and server rooms - detection and location of water leaks beneath raised floors, above suspended ceilings, and along service routes.
  • Direct Liquid Cooling (DLC) - location of water and conductive coolant leaks around coolant distribution units (CDUs), direct-to-chip systems, manifolds, and liquid-cooling distribution lines.
  • Glycol cooling circuits - detection of leaks involving water mixtures with propylene glycol or ethylene glycol used in HVAC and industrial cooling.
  • Heating, ventilation, and air conditioning (HVAC) - monitoring leaks from air-conditioning units, chillers, fan-coil units, and condensate drain pipes.
  • Piping routes - a location sensing cable installed along piping not only detects a leak but also identifies its position along the cable route.
  • Plant rooms and boiler rooms - detection of leaks from boilers, pumps, valves, heat exchangers, and water tanks.
  • Commercial and office buildings - protection of rooms, floors, and technical areas using a location cable installed along walls, floors, or critical routes.
  • Hotels - monitoring bathrooms, corridors, and service areas where even a small water leak can cause damage across multiple floors.
  • Hospitals and laboratories - location of water leaks in areas containing sensitive technology, laboratory equipment, or critical infrastructure.
  • Warehouses, archives, and storage facilities - early detection and location of water ingress before goods, documents, or stored materials are damaged.
  • Basements and service floors - detection of flooding, seepage, and groundwater ingress along long monitored routes.
  • Industrial facilities - monitoring pipelines, tanks, process lines, and production equipment while identifying the location of a liquid leak.


ProdGrafik

Detected liquids

The WLD-Location cable L responds to electrically con- ductive liquids. It detects water, water-propylene gly- col mixtures, water-ethylene glycol mixtures, and other electrically conductive liquids. Typical examples include Dowfrost, DOWTHERM SR-1, Tyfocor, and Antifrogen.
  • Detection depends on the electrical conductivity and concentration of the specific liquid.
  • Can be easily dried after flooding and reused.



WLD / WLD-L port

A green 4-pin "WLD-L" port is required to connect the yellow WLD-Location cable L.
  • Only WLD Type A and Type B sensing cables can be connected to a 2-pin WLD port.
  • The WLD-Location cable L is connected to the device using the 5m "WLD-Connecting cable L 5m". Distance is measured from the beginning of the yellow location cable; the 5 m connecting cable is excluded.
  • A special feature of the WLD-L port used to locate flooding is that it can also operate as two independent 2-pin WLD ports after the device configuration is changed.




General specifications
Cable material Fluoropolymer, PVC
Length variants 10 m, 50 m, custom
Max. cable length 100 m
Cable diameter (Ĝ) 6 mm
Electrically insulated surface ✖
Terminator Required



Technical parameters
Leak location accuracy ± 4% of the cable length (± 0.4 m for a 10 m cable)
Leak detection response time 15 - 30 seconds
Cable diameter (Ĝ) 6 mm
Min. bend radius 25 mm
Min. wetted cable length 15 mm
Min. liquid depth 3 mm
Connector 4-pin (locking connector)
Connection to the WLD-L port   WLD-Connecting cable L 5m




Ordering Information


  Leak Detection (zone) Leak Location (distance) Connection port Max. length
WLD-Sensing cable A ✔ ✖ WLD / WLD-L 185 m
WLD-Sensing cable B ✔ ✖ WLD / WLD-L 185 m
WLD-Location cable L ✔ ✔ WLD-L 100 m